Dust Collector
Dust Collector is a system used to improve air quality released from industrial and commercial processes by collecting dust and other impurities from air or gas. Designed to handle high-volume dust loads, the dust collection system consists of a blower, a dust collector cartridge filter, a jet filter / Shaker dust collector system, and a dust container or dust disposal system.
Dust Collector Chamber is a dust collector with a simple working principle. bag house dust collector is made open to remove clean air that has been caught in the filter room.
Dust collector chamber can be an alternative company to overcome air pollution from the production process at a cost that is not so large but the results can be felt.Working Principle of Dust Collector:System bag filter or Dust Collector system is a unit consisting of ducting, filter bag and blower. Its function is to suck particles or dust produced from the results of the production process from the production room, then filter it on the filter bag so that the air that comes out becomes clean.
Particles or dust move from the suction hole through line ducting - bag - blower filter. Dust and particles enter into the dirty air space in the filter bag, most of the particles will fall in the hopper and the rest will be filtered and stick to the outer wall of the filter bag, so that clean air comes out of the inner wall of the filter bag towards the clean air space sucked by the blower , then to free air.Bag filter or dust collector system which is equipped with pulse jet cleaning, which is a filter bag cleaner using 4-6 bar pressurized air. The air from the compressor collects in the Header. At the time of air cleaning the solenoid valve valve will open flowing compressed air into the filter bag to knock out the dust layer on the outer wall of the filter bag. The opening time is 0.4 seconds. 1 opening will clear 1 lane filter bag.
The time interval between the opening of a solenoid valve and the next 1 valve solenoid valve is in the 15 second set. This arrangement is carried out by the PLC unit or Squen dust collector in the panel. The interval and opening time of the solenoid valve can be adjusted at any time in the PLC or Squen Dust Collector settings to follow the needs. All the dust particles that fall off or fall directly into the hopper are then stored in the dust bin (under the hopper).